Certification: | RoHS, CCC, ISO9001, CE |
---|---|
Working Medium: | R32 |
Heat Source Type: | Air Source Heat Pump |
Delivery Time: | 40-65days |
Color: | Silver/Customized |
Power Supply: | 380V/3pH/50Hz |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Model Code | CHP-8III/CD3 | CHP-10III/CD3 | CHP-12III/CD3 | CHP-14III/CD3 | CHP-16III/CD3 | |||
Power Supply | V/ph/Hz | 380-420/3/50 | ||||||
A7/W35 | Heating Capacity | KW | 8 | 10 | 12 | 14 | 16 | |
Heating Power Input | KW | 1.63 | 2.28 | 2.47 | 2.99 | 3.39 | ||
COP | W/W | 4.91 | 4.39 | 4.86 | 4.69 | 4.72 | ||
A-7/W35 | Heating Capacity | KW | 7.13 | 8.41 | 10.5 | 12.6 | 13.4 | |
Heating Power Input | KW | 2.38 | 2.8 | 3.48 | 4.34 | 4.41 | ||
COP | W/W | 3.00 | 3.00 | 3.02 | 2.9 | 3.04 | ||
A-7/W52 | Heating Capacity | KW | 6.8 | 8.5 | 10.6 | 12 | 12.5 | |
Heating Power Input | KW | 3.4 | 4.25 | 5.02 | 5.94 | 5.79 | ||
COP | W/W | 2.00 | 2.00 | 2.11 | 2.02 | 2.16 | ||
A-10/W55 | Heating Capacity | KW | 6.60 | 7.00 | 8.98 | 10.8 | 11.3 | |
Heating Power Input | KW | 3.47 | 3.68 | 5.19 | 5.93 | 5.95 | ||
COP | W/W | 1.90 | 1.90 | 1.73 | 1.82 | 1.90 | ||
A35/W18 | Heating Capacity | KW | 7.00 | 9.20 | 10.6 | 13.1 | 13.4 | |
Heating Power Input | KW | 1.52 | 2.00 | 2.57 | 3.25 | 3.54 | ||
COP | W/W | 4.60 | 4.60 | 4.13 | 4.03 | 3.78 | ||
A35/W7 | Cooling Capacity | KW | 6.40 | 7.90 | 10.5 | 12 | 13.6 | |
Cooling Power Input | KW | 2.13 | 2.43 | 3.68 | 4.21 | 4.98 | ||
EER | W/W | 3.00 | 3.25 | 2.85 | 2.85 | 2.73 | ||
Max input cerrent | A | 22 | 26 | 13 | 15 | 16 | ||
Max input power | KW | 4.4 | 5.3 | 6.5 | 7.4 | 8 | ||
Sound Power Level (EN12102 35ºC) | dB(A) | 56 | 58 | 60 | 62 | 64 | ||
Net/Gross weight | kg | 105/115 | 105/115 | 125/140 | 125/140 | 142/162 | ||
Operating Ambient Temperature | ºC | -25ºC-43ºC | ||||||
Water Flow | m3/h | 1.38 | 1.72 | 2.06 | 2.41 | 2.75 | ||
Unit outdoor Dimensions (L*W*H) | mm | 1091*424*798 | 1091*424*973 | 1091*424*1363 | ||||
Shipping Dimensions (L*W*H) | mm | 1162*518*885 | 1162*518*1060 | 1162*518*1450 |
* A7/W35:Performance Condition: Outdoor air 7ºC/6ºC, Inlet/Outlet water 30ºC/35ºC | |||||||||||||||
* A-7/W35:Performance Condition: Outdoor air -7ºC/-8ºC, Inlet/Outlet water 30ºC/35ºC | |||||||||||||||
* A-7/W52:Performance Condition: Outdoor air -7ºC/-8ºC, Inlet/Outlet water 44ºC/52ºC | |||||||||||||||
* A-10/W55:Performance Condition: Outdoor air -12ºC/-10ºC, Inlet/Outlet water 47ºC/55ºC | |||||||||||||||
* A35/W7:Performance Condition: Outdoor air 35ºC/24ºC, Inlet/Outlet water 7ºC/6ºC | |||||||||||||||
* A35/W18:Performance Condition: Outdoor air 35ºC/24ºC, Inlet/Outlet water 23ºC/18ºC | |||||||||||||||
* The above data is for reference only; specific data is subject to the product nameplate. | |||||||||||||||
* The above models and specification are for reference only,we can also make the OEM or ODM as per the customer's needs. |
At Guangdong Geme Refrigeration Equipment Co., Ltd, we take pride in offering top-notch OEM and ODM services for heat pumps. Whether you need standard products under your brand or personalized designs, we can meet your requirements with our efficient manufacturing processes.
Our factory, located in Foshan city, Guangdong Province, boasts an annual output capacity of 1,000,000 sets per year, supported by 6 production lines. We ensure excellent technical support with manuals, online assistance, and the option for on-site training by our experts.
Our heat pumps are popular in Western Europe, Eastern Europe, Central, and Southeast Asia. We offer flexible payment terms, accepting T/T with a 30% deposit and LC AT SIGHT. The standard delivery time for our heat pumps is 50-65 days, and we welcome small orders for negotiation.
Choose Guangdong Geme Refrigeration Equipment Co., Ltd for high-quality products and exceptional service. Contact us now to discuss your requirements and place an order.
Suppliers with verified business licenses